17:02:27 EDT Sun 28 Apr 2024
Enter Symbol
or Name
USA
CA



Kermode Resources Ltd (2)
Symbol KLM
Shares Issued 34,242,072
Close 2024-02-27 C$ 0.01
Market Cap C$ 342,421
Recent Sedar Documents

Kermode assays 25.59% Cu at Mount Sicker

2024-03-06 00:35 ET - News Release

Mr. Peter Bell reports

KERMODE REPORTS XRF RESULTS FOR SAMPLES FROM 911 SHOWING

Kermode Resources Ltd. has released assay results for grab samples from the 911 showing at the Mount Sicker project. Note that all samples were taken from bedrock and collected by Justin Deveault and Justin McNutt from 911 Exploration Corp. on Jan. 14, 2024. The XRF results were received March 4, 2024.

            SAMPLE RESULTS

Sample No.                     Copper (%)

D725001                            10.27%
D725002                            11.01%
D725003                            25.59%
D725004                            14.08%
D725005                            12.33%
D725006                            17.64%
D725007                            19.61%

Qualified person

The technical information in this news release has been reviewed and approved by Jacques Houle, PEng, a qualified person responsible for the scientific and technical information contained herein under National Instrument 43-101 standards.

Quality assurance/quality control statement

The results reported herein were prepared by using an Olympus Delta portable XRF (model DS 6500CC) using industry standard chain of custody procedures with all samples. The XRF operator named Clive Khan is independent of Kermode and completed the XRF analysis in February, 2024.

The XRF was calibrated prior to each test as follows. At each start-up, a calibration coin was analyzed, and subsequent analysis was only performed when a pass was obtained, which was calculated internally by the XRF instrument. The XRF unit was set to geochemical mode, and a full 200-second test was run to determine copper content. While the instrument detects many elements, only copper was tested. The XRF analyzes only a small portion of the sample, so half the sample was crushed to pass an 80-mesh screen before testing. During analysis of the samples by hand-held XRF, non-blind control samples were analyzed to monitor the XRF instrument calibration and performance. A correction factor for all base metals was applied to the raw data. The correction factor was determined by analyzing samples that had previously been analyzed at a commercial laboratory. These rock samples were of varying concentrations and analyzed by the hand-held XRF using the method described above. The portable XRF is accurate to within a 5-per-cent error for copper content. The company did not use the portable XRF to determine accurate readings for other elements.

About Kermode Resources Ltd.

Kermode is a junior mining company hunting for exploration opportunities around the world.

We seek Safe Harbor.

© 2024 Canjex Publishing Ltd. All rights reserved.