Mr. James Hill reports
GASFRAC ENERGY SERVICES INC. ANNOUNCES INCIDENT INVESTIGATION RESULTS
Gasfrac Energy Services Inc. has completed the investigation of the incident described in the Stockwatch press release of Jan. 17, 2011. The investigation was conducted by third party fire investigators working with Gasfrac personnel. The investigation concluded that a brief propane flash caused the ignition of lubricating fluids and tires on two fracturing pumpers. The isolation systems in place prevented any propane combustion beyond the initial brief flash. It was further determined that the cause of the leak was a premature mechanical failure of the low-pressure side of the suction manifold of one of the quintiplex pumps. The company has determined detailed corrective actions to prevent any recurrence and is in the process of implementing these actions and has targeted Jan. 31, 2011, for recommencement of operations.